Contact Us
Kentex Vital Signs Monitor
Product # 500200B
  • NIBP button on the front panel, directly measuring the NIBP with pushing the
    button
  • Vehicle inverter: unlimited using time for ambulance without the AC adapter
  • Compact design, light weight (1.8kg)
  • Easy-to-use: Big screen, with bracket
  • 72-hour data storage, 99 ID set available, measurement record and trend
    review
  • Bright, high resolution LCD screen to display the Pleth waveform as well as
    the SpO2 and pulse rate readings
  • Separate bright LED displays for systolic, diastolic and mean blood pressure
    readings
  • Printer facility for printing reports immediately
  • Patient measuring data transfer via USB to a PC
FEATURES
TECHNICAL SPECIFICATIONS
Classification
Compact and transportable vital signs monitor, providing the effective and
accurate SpO2, NIBP, and pulse rate measurement. Also, the thermal recorder,
data transmission function, vehicle inverter, and product backpack are reserved
for users. It is widely applied in hospitals, nursing homes, EMS, dialysis clinics and
surgical centers.
Protection class
Type BF defibrillation proof
Protection against moisture
IPX1
Safety
IEC 60601-1
Patient Range
Adult, pediatric, and infant
Appearance
Dimension
296mm(11.65") x 166mm(6.54") x
96mm(3.78")
Weight
1.8kg (3.97lb), including batteries
Display
Environmental
Storage
Alarm
Data Transmission (Optional)
NIBP
Battery
Type
3.5" LCD & LED screen
Parameters
NIBP (SYS, DIA, MAP), SpO2, PR, pulse bar, plethysmograph
Power
AC 100 - 230V, 50/60Hz (±3Hz)
Operation temperature
5° - 40°C (41° - 104°F)
Storage temperature
-20° - 55°C (-4° - 131°F)
Operation humidity
≤80%, non-condensing
Storage humidity
0-93%, non-condensing
USB
Flash disk
Wired LAN to choice central monitoring system
Alarm
NIBP (SYS, DIA, MAP), SpO2, PR, probe off, finger out, low voltage
Modes
Visible & 3-level audible alarms, error code
Patient ID
1-99
Data records
Up to 72 hours
Type
Built-in rechargeable battery
Operation time
More than 2 hours (continuous operation)
Method
Oscillometric
Operation modes
Manual/Automatic/STAT
Measurement unit
mmHg/kPa selectable
Measurement types
Systolic, Diastolic, and Mean
Measurement range
  Infant
Adult
SYS
30-135
30-255
DIA
15-110
15-220
MAP
20-125
20-235
Over-pressure protection
Yes
Resolution
1mmHg
Optional Configuration
SpO2
Standard Configuration
Printer
Pulse Rate
Measurement range
70%-100%
Accuracy
80%-100%: ±2%
70%-79%: ±3%
0%-69%: unspecified
Measurement range
30-235bpm
Resolution
1bpm
Accuracy
30-100: ±2bpm
101-235: ±2%
Type
Built-in thermal recorder
Width of printing paper
Standard 50 (+0/-1) 8mm
SpO2, PR, NIBP
USB data transmission, choice central monitoring system, thermal recorder, car
inverter
Nashville EMS